Room Sensor

CO2/Temperature/RH Room Sensor

  • Comply with Part F guidance
  • Monitor/ Measure carbon dioxide (CO2), temperature and relative humidity
  • Suitable for +24V AC/DC and 230V 50/60Hz supplies
  • Linear +10V output to regulate speed controllers or EC fans
  • VFC relay for alarm signal on CO2 level
  • BACnet or Modbus options
  • LED Indicator for CO2 levels (Red/Yellow/Green)
Select Models Available Next Day

Quantity

Got a question about this product?

Email us or call us on +44 (0) 1384 275800

Compatible Accessories

Overview

A Range of Room sensors to monitor and measure carbon dioxide (CO2), temperature and relative humidity. Designed for all areas being directly connected to low or mains voltage supply. Suitable for connection to a Variable Frequency Drive or directly to an EC Fan.

Features and Benefits

Supply Voltage

The Room Sensor uses a supply voltage of +24V AC/DC or 230V 50/60Hz.

Analogue Outputs

Three Analogue 0-10V outputs are available, 1 x CO2, 1 x Temperature, 1 x Relative Humidity.

Digital Outputs

RS-485 Modbus RTU or BACnet MS/TP communication protocols available dependent on model.

Standalone Use

Can be used without output connections as a monitor only of CO2, Temperature or Relative Humidity

Traffic Light CO2 System

LED Indicator for visual identification of CO2 Levels, Green – OK, Yellow – Low, RED – High.

Specification

The EC-CO2TH3(B/M) Room Sensor as supplied by Elta Limited shall include the following control functions as standard:

Monitoring of CO2, Temperature and Relative Humidity

A configurable 0/2-10V linear output for CO2 (PPM), Temperature (C/F°) and Humidity (rH%) shall be provided for connection to BMS systems and to regulate speed controllers or EC fans. During normal operation, the output of the device is proportional to the values.

A dry contact/volt free connection to a BMS (building management system) or central control panel to send an alarm signal upon the defined CO2 level shall be provided. This terminal can be used in conjunction with other external relays that affect other devices, and controls such as purge fans, audible alarms, strobe/beacons.

Power supply shall be via +24V AC/DC or 230V 50/60Hz

LED Indication of CO2 levels shall be visually identified by Green – OK, Yellow – Low, and RED – High.

Digital connection via RS-485 Modbus RTU or BACnet MS/TP communication protocols shall be available dependent on model

Interested? Make an Enquiry

Customers Also Viewed

Thermistor Protection Relay

Thermistor Protection Relay

Select Available Next Day
Transformer Controllers
Options Available

Transformer Controllers

Select Models Available Next Day
Airflow Fault Monitor

Airflow Fault Monitor

Select Available Next Day
Room Thermostat Room Thermostat

Room Thermostat

Select Available Next Day